Posted by on Monday, 14 October, 2013

Heaters at the facility should be included after the circulation of material on and off for at least 5 minutes before turning off the circulation at the end of painting. For mixing the coating components, stirring device is used, it should work in the circulation time and the coating. Preparation of material in accordance with the manufacturer's recommendations material. Application of external anticorrosion coating Painters, move the products produced in cell staining. The painter controls the chamber temperature and humidity, dew point defines, controls surface temperature products using the appropriate instruments. Measuring partings should be believed. If the product temperature above the dew point of at least 3C, it is possible to coat the surface products.

If the surface temperature of the products is lower than in 3C dew point, it produced extra heating products in the chamber. Operating modes of the coating produced in accordance with the recommendations of the manufacturers materials. Coating products made on the length of the product, at the ends are recommended for several passages in diameter. Pistol to keep at a distance of 40-50 cm from the product and move it so that the torch was perpendicular to the insulated surface. The coating on the product to produce plots in the form of bands on several passes, applied band coverage should cover the band from a previous application to 1 / 3. The coating on the product is applied in several passes. The number of passes determined by the size and shape of the product. In order to prevent adding water stains, and a coating of uniform thickness recommended 5 – 10 passages when applied to each regular band.

Number of passes depends on the experience of the painter, area coverage, nozzle diameter nozzle. Coating of articles with complex configuration should start with the most difficult areas, then move on to the rest of the surface. When applied to control the thickness of the wet layer is necessary to use the comb. In the process of coating products must be applied coating on witness samples for testing the quality of coverage. Produce the control of coating thickness using an instrument designed to measure the thickness of nonmagnetic coatings. At sites with inadequate thickness cause an extra layer of coverage. The time between applying the base layer coating and an additional layer depends on the material. If you exceed the time, before the application is necessary to make preliminary preparation of the coating. Strip off the coating surface using a grinding machine and dedusted vacuumed or cleaned with compressed air. Produce the control of coating thickness in the field application an additional layer using an instrument to measure the thickness of the coating. The pressure difference on the gauge painting installation at the time of application should be no more than 30 bar. In the case of greater pressure difference to make adjustments in according to the manual installation. Products that are installed on the stand can be removed after a certain time depending on the material properties. Quality control and acceptance of products with the outer corrosion-resistant coating provides otc manufacturer.

Press Service

Posted by on Saturday, 5 November, 2011

When choosing windows should be aware that their quality is determined by such components as the profile, fittings, sealing glass or glass. An important factor on which depends the life of the windows, – Professional installation and setup. According to a study by an American corporation Bank of America Home Equity and the National Association of Home Builders U.S., the average lifespan of windows from 15 to 30 years. Aluminium windows able to withstand about 15 years, wood – not more than 30. Several decades ago, an alternative to wooden frames were not, but today there are windows made of PVC-profile life that can reach 40 or more years. For example, life Profile proplex is over 60. Manufacture of such a profile deals Russia's largest producer of pvc window-profile of Austrian technologies – Group propleks.

To determine the lifetime of the windows used the device "Ksenotest, imitating different weather conditions: all kinds of precipitation, temperature, humidity fluctuations, ultraviolet radiation, etc. During the two-week test sample is exposed, plastic window which stands for a lifetime. In this case, plastic is suitable for installation in all climatic conditions. Thus, the test profile proplex held at a temperature of -55 C. In reality, the window of the product already few years have been successfully used in the Far North, where the temperature is and below. Conclusion In the past few years the rate of construction of country houses and cottages have acquired an unprecedented scale – the "construction boom" in Russia does not say except that lazy. Nevertheless, the construction of his house that is guaranteed will stand for decades, still remains a challenge.

Experts identify three major errors that adversely affect on the durability of the structure. This is, first of all, mistakes and errors made in the design phase. The second common mistake is associated with the construction of substandard materials and designs. and The third factor – poor knowledge of implementing construction techniques. The reason for all these errors is almost unanimously recognized as an unprofessional approach. This means that the house – so he could move through the generations – a better to professionals. Press Service of the Group PROPLEKS